General installation principles per product family. Detailed instructions are on the manufacturers' sites. Installation guidance by phone.
Surface preparation and installation per product family
Covalence is shrunk with a flame, Stopaq is pressed on cold, and the BG Industry sleeve is either heat-shrunk or electro-welded with a built-in welding band. The surface-prep requirement differs in each.
Wrap-around heat‑shrink sleeve for the joint casing of pre‑insulated pipe
Surface prep: The surface must be dry, clean and rust-free, at above +10 °C. Moisture stays trapped between sleeve and pipe if the surface is not dried properly.
Installation: The method is heat shrink: the sleeve is wrapped around the joint and shrunk into place on site. The backing carries an indicator that shows when the shrink has taken. Sleeve width follows the size of the joint, and we help with the selection. Alongside the sleeve, Covalence also supplies end caps, repair patches and the other joint accessories.
Check: Verify the sleeve has shrunk evenly across the joint and that adhesive has flowed at the edges. Both indicate a successful seal.
Cold-applied visco-elastic corrosion protection for steel pipe
Surface prep: This is the whole point of Stopaq: ST2 surface preparation is enough. Rust does not need to be ground off and may stay under the coating, as long as the surface is clean of dirt. No primer, no blasting.
Installation: The wrap is pressed on by hand. The visco-elastic compound flows into surface irregularities and forms a continuous seal without heating. A mechanical overwrap such as Outerwrap goes on top.
Check: The compound never dries, because it is an organic material. It shuts out oxygen and electrolyte, so the oxidation process stops. Small mechanical damage self-heals.
Prefabricated shrink sleeve for the joint between two pre‑insulated pipes
Surface prep: Clean and dry the casing surface where the sleeve bonds. The sleeve is chosen from a standard size series to match the pipe, so measuring and cutting fall away.
Installation: The shrink sleeve is placed over the joint and heat-shrunk tightly around the casing; butyl mastic seals the connection. The electro-weldable sleeve has a welding band built into it: it is welded to the casing with a welding machine, the same machine used for other electro-weldable sleeves.
Check: The joint is leak-testable, so its dryness can be verified before backfilling. Branches and terminations use their own products (tee and end sleeves).
Installation guidance and quotes
We walk through the installation by phone, and where needed we come to site to guide the installers. Materials and a quote from the same Tuusula warehouse.
Manufacturers' installation instructions